Svanhvid/macros/sensorless-homing.cfg

46 lines
1.6 KiB
INI

[gcode_macro _HOME_X]
gcode:
SAVE_GCODE_STATE NAME=HOMING_X
# Always use consistent run_current on A/B steppers during sensorless homing
{% set RUN_CURRENT_X = printer.configfile.settings['tmc2209 stepper_x'].run_current|float %}
{% set RUN_CURRENT_Y = printer.configfile.settings['tmc2209 stepper_y'].run_current|float %}
{% set HOME_CURRENT = 0.8 %}
SET_TMC_CURRENT STEPPER=stepper_x CURRENT={HOME_CURRENT}
SET_TMC_CURRENT STEPPER=stepper_y CURRENT={HOME_CURRENT}
# Home
G28 X F2400
# Move away
G91
G1 X-10
# Wait just a second… (give StallGuard registers time to clear)
G4 P1000
# Set current during print
SET_TMC_CURRENT STEPPER=stepper_x CURRENT={RUN_CURRENT_X}
SET_TMC_CURRENT STEPPER=stepper_y CURRENT={RUN_CURRENT_Y}
RESTORE_GCODE_STATE NAME=HOMING_X
[gcode_macro _HOME_Y]
gcode:
SAVE_GCODE_STATE NAME=HOMING_Y
# Set current for sensorless homing
{% set RUN_CURRENT_X = printer.configfile.settings['tmc2209 stepper_x'].run_current|float %}
{% set RUN_CURRENT_Y = printer.configfile.settings['tmc2209 stepper_y'].run_current|float %}
{% set HOME_CURRENT = 0.8 %}
SET_TMC_CURRENT STEPPER=stepper_x CURRENT={HOME_CURRENT}
SET_TMC_CURRENT STEPPER=stepper_y CURRENT={HOME_CURRENT}
# Home
G28 Y F2400
# Move away
G91
G1 Y-10
# Wait just a second… (give StallGuard registers time to clear)
G4 P1000
# Set current during print
SET_TMC_CURRENT STEPPER=stepper_x CURRENT={RUN_CURRENT_X}
SET_TMC_CURRENT STEPPER=stepper_y CURRENT={RUN_CURRENT_Y}
RESTORE_GCODE_STATE NAME=HOMING_Y